Hyundai Equus Manuals

Hyundai Azera: Fuel Tank Air Filter Repair procedures - Evaporative Emission Control System - Emission Control System - Hyundai Azera 2011-2025 Service ManualHyundai Azera: Fuel Tank Air Filter Repair procedures

Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Lift the vehicle.
3.
Disconnect the canister close valve connector (A).
4.
Disconnect the ventilation hose (B) from the fuel tank air filter and canister close valve.
5.
Remove the fuel tank air filter assembly after removing bolts (C).

6.
Release the lever (A), and then separate the canister close valve (B) from the fuel tank air filter (C) after rotating it in the direction of the arrow in the figure.

Installation
Install the component with the specified torques.
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
1.
Installation is reverse of removal.
Fuel Filler Cap Description and Operation
Description A ratchet tightening device on the threaded fuel filler cap reduces the chances of incorrect installation, which would seal the fuel filler. After the gasket on the fuel filler cap ...

Exhaust Emission Control System
...

See also:

Hood Latch Repair procedures
Replacement 1. Remove the front bumper cover. (Refer to Front Bumper - "Front Bumper Cover") 2. Detach the clips, then remove hood latch cover (A). 3. Remove the hood latch (A) mounting b ...

Trunk
...

Engine Mounting Repair procedures
Removal and Installation [Engine mounting support bracket] 1. Install the jack to the edge of upper oil pan (A) to support the engine.     Insert the rubber block between jac ...

Categories

Hyundai Azera Manuals


© 2011-2025 Copyright www.hgmanual.com