Inspection |
1. |
Ignition "OFF". |
2. |
Disconnect the intake actuator connector. |
3. |
Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 7. |
4. |
Verify that the intake actuator operates to the fresh position when connecting in the reverse.
|
5. |
Check the voltage between terminals 5 and 6.
Specification
|
6. |
If the intake actuator is not operated well, substitute with a known-good intake actuator and check for proper operation. |
7. |
If the problem is corrected, replace the intake actuator. |
Replacement |
1. |
Disconnect the negative (-) battery terminal. |
2. |
Remove the crash pad.
|
3. |
Disconnect the Intake actuator connector (A). |
4. |
Loosen the mounting screw and then remove the intake actuator (B). |
5. |
Installation is the reverse order of removal. |
Specifications
Specifications
ItemsSpecificationHoodTypeRear hinged, gas lifter typeFront DoorConstructionFront hinged, full door constructionRegulator systemWire drum typeLocking systemPin-fork systemRear Door ...
Torque Converter Control Solenoid Valve (T/CON_VFS) Repair procedures
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the solenoid valve connector.
3.
Measure resistance between sensor signal terminal and sensor ground terminal.
4.
Check that the ...
Passive Occupant Detection System (PODS-F) Description and Operation
Description
In order to make normal activation of airbag system, SRSCM
detects DTC(s) for the Passive occupant detection system (PODS-F). If