Hyundai Equus Manuals

Hyundai Azera: Heated Oxygen Sensor (HO2S) Specifications - Engine Control System - Engine Control/Fuel System - Hyundai Azera 2011-2025 Service ManualHyundai Azera: Heated Oxygen Sensor (HO2S) Specifications

Specification
[Bank 1 / sensor 2, Bank 2 / sensor 2]
A/F Ratio (?)
Output Voltage(V)
RICH
Min. 0.8
LEAN
Max. 0.1

Item
Specification
Heater Resistance (?)
3.3 ~ 4.1[20°C(68°F)]

[Bank 1 / sensor 1, Bank 2 / sensor 1]
A/F Ratio (?)
Output Voltage(V)
RICH
0.6 ~ 1.0
LEAN
0 ~ 0.4

Item
Specification
Heater Resistance (?)
About 9.0[20°C(68°F)]

Heated Oxygen Sensor (HO2S) Description and Operation