[Bank 1 / sensor 2, Bank 2 / sensor 2]
A/F Ratio (?)
| Output Voltage(V)
|
RICH
| Min. 0.8
|
LEAN
| Max. 0.1
|
Item
| Specification
|
Heater Resistance (?)
| 3.3 ~ 4.1[20°C(68°F)]
|
[Bank 1 / sensor 1, Bank 2 / sensor 1]
A/F Ratio (?)
| Output Voltage(V)
|
RICH
| 0.6 ~ 1.0
|
LEAN
| 0 ~ 0.4
|
Item
| Specification
|
Heater Resistance (?)
| About 9.0[20°C(68°F)]
|
Description
Heated Oxygen Sensor (HO2S) consists of the zirconium and the
alumina and is installed on upstream and downstream of the Warm-up
Catalytic Converter (WCC).
After it compares oxygen ...