SS-B Solenoid Valve(ON/OFF) Description and Operation
Description
SS-B solenoid valve is attached to the valve body and is an
on/off solenoid valve that is used to change gears. SS-B Solenoid
valve(ON/OFF) is installed at valve body. ...
35R Clutch Control Solenoid Valve(35R/C_VFS) Description and Operation
Description
35R clutch control solenoid valve(35R/C) is attached to the
valve body. This variable force solenoid valve directly controls the
hydraulic pressure inside the 35R clutch. ...
Cluster ionizer Repair procedures
Inspection
1.
Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch.
DisplayFail description00Normal50Cluster ionizer fault
* Diagnostic procedure refer to D ...