Replacement |
1. |
Remove the condenser, and then remove the bottom cap (B) with L wrench (A) from the condenser.
|
2. |
Remove the desiccant (A) from condenser using a long nose plier. Check for crumbled desiccant and clogged bottom cap filter. |
3. |
Apply air conditioning compressor oil along the O-rings and threads of the new bottom cap. |
4. |
Insert the new desiccant into the receiver drier tank. The
desiccant must be sealed in vacuum before it is exposed to air for use. |
5. |
Install the new bottom cap to the condenser.
|