Hyundai Equus Manuals

Hyundai Azera: Refrigerant line Repair procedures - Air Conditioning System - Heating,Ventilation, Air Conditioning - Hyundai Azera 2011-2024 Service ManualHyundai Azera: Refrigerant line Repair procedures

Replacement
1.
Discharge refrigerant from refrigeration system.
2.
Replace faulty tube or hose.
   
Cap the open fittings immediately to keep moisture or dirt out of the system.
3.
Tighten joint of bolt or nut to specified torque.
   
Connections should not be torque tighter than the specified torque.
4.
Evacuate air in refrigeration system and charge system with refrigerant.

Specified amount : 19.4 ± 0.88 oz.(550 ± 25g)

5.
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
6.
Inspect A/C operation.
Refrigerant line Components and Components Location
Component Location ...

Compressor Components and Components Location
Components 1. Screw2. Bolt3. Limiter Assembly4. Retainer Ring5. Pulley6. Connector Bracket7. Compressor Assembly ...

See also:

Knee Airbag (KAB) Module Components and Components Location
Components ...

Engine Room Under Cover Components and Components Location
Components 1. Engine room front under cover2. Engine room RH Under cover3. Engine room LH Under cover ...

Disarmed stage
The system will be disarmed when: - The door unlock button is pressed on the smart key. - The switch of the front outside door is pressed while carrying the smart key. - The door is opened with the ...