Hyundai Equus Manuals

Hyundai Azera: Blower Motor Repair procedures - Blower - Heating,Ventilation, Air Conditioning - Hyundai Azera 2011-2024 Service ManualHyundai Azera: Blower Motor Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Disconnect the of the blower motor connector(A) and then remove the blower motor (B).

4.
Installation is the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit. (Refer to Heater - "Heater Unit") 3. Remove the blower unit (A) from the heater unit ...

Power Mosfet Repair procedures
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. 1. Drain2. Dr ...

See also:

TPMS (Tire Pressure Monitoring System) malfunction indicator
The TPMS malfunction indicator will illuminate after it blinks for approximately one minute when there is a problem with the Tire Pressure Monitoring System. If the system is able to correctly det ...

Road warning
...

Roof Side Molding Repair procedures
Replacement [General Type]     • When prying with a flat-tip screwdriver, wrap it with protective tape, and apply protective tape around the related parts, to prevent dama ...

Categories

Hyundai Azera Manuals


© 2011-2024 Copyright www.hgmanual.com