Inspection
1.
Connect the battery voltage and check the blower motor rotation.

2.
If the blower motor voltage is not operated well, substitute with a known-good blower motor and check for proper operation.
3.
If the problem is corrected, replace the blower motor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad lower cover (A) and then disconnect the connector (B).

3.
Disconnect the of the blower motor connector(A) and then remove the blower motor (B).

4.
Installation is the reverse order of removal.
Blower Unit Repair procedures
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater and blower unit. (Refer to Heater - "Heater Unit") 3. Remove the blower unit (A) from the heater unit ...

Power Mosfet Repair procedures
Inspection 1. Ignition "ON" 2. Manually operate the control switch and measure the voltage of blower motor. 3. Select the control switch to raise voltage until high speed. 1. Drain2. Dr ...

See also:

Fuel Pump Repair procedures
Inspection [Fuel pump] 1. Turn the ignition switch OFF, and then remove battery (-) cable. 2. Remove the fuel pump assembly. 3. Check motor operation by fuel pump connector (A) connecti ...

Rail Pressure Sensor (RPS) Troubleshooting
Signal Waveform ...

Engine Room Under Cover Repair procedures
Removal and Installation 1. Remove the engine room under cover (A) and (B). Tightening torque: 7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)     • When removing the ...

Categories

Hyundai Azera Manuals


© 2011-2025 Copyright www.hgmanual.com